  gas generator set GS100-6S 100 kwe / 60 hz / standby 208 - 600v system ratings voltage (l-l) 240v** 240v** 208v** 240v** 480v** 600v** phase 1 1 3 3 3 3 pf 1 1 0.8 0.8 0.8 0.8 hz 60 60 60 60 60 60 natural gas ratings: amps 417 417 347 301 151 120 natural gas ratings: kw/kva 100/100 100/100 100/125 100/125 100/125 100/125 lp gas ratings: amps 417 417 347 301 151 120 lp gas ratings: kw/kva 100/100 100/100 100/125 100/125 100/125 100/125 skva@30% voltage dip 311 130 258 258 344 277 generator model* 363csl1617 431csl6204 362csl1606 362csl1606 362csl1606 362psl1636 temp rise 130 c/40 c 130 c/40 c 130 c/40 c 130 c/40 c 130 c/40 c 130 c/40 c connection 4 lead 12 lead zig-zag 12 lead low wye 12 lead hi delta 12 lead hi wye 4 lead wye ** ul 2200 o ? ered note: this unit is available with a dual fuel con guration. // ? generator set is designed and manufactured in facilities certi ed to standards iso 9001:2008 and iso 14001:2004 // ? ul 2200 / csa ? optional ? ul 2200 listed ? csa certi ed // ? performance assurance certification (pac) - generator set tested to iso 8528-5 for transient response - veri ed product design, quality and performance integrity - all engine systems are prototype and factory tested // ? power rating - accepts rated load in one step per nfpa 110 certifications and standards standby (ng) gs100n6sdt gs100n6sgt gs100n6spt gs100n6sjt gs100n6srt gs100n6snt standby (lp) gs100l6sdt gs100l6sgt gs100l6spt gs100l6sjt gs100l6srt gs100l6snt
2 // / ? / GS100-6S // ? engine heavy duty air cleaner oil pump oil drain extension & s/o valve full flow oil filter jacket water pump thermostat blower fan & fan drive radiator - unit mounted electric starting motor - 12v governor ? electronic isochronous base - formed steel sae flywheel & bell housing charging alternator - 12v battery rack & cables flexible exhaust connection liquid cooled, ball bearing turbocharger epa certi ed engine // ? generator nema mg1, ieee and ansi standards compliance for temperature rise and motor starting sustained short circuit current of up to 300% of the rated current for up to 10 seconds self-ventilated superior voltage waveform solid state, volts-per-hertz regulator 1% voltage regulation no load to full load brushless alternator with brushless pilot exciter 4 pole, rotating field 130 c maximum standby temperature rise 1 bearing, sealed flexible coupling full amortisseur windings 125% rotor balancing 3-phase voltage sensing 100% of rated load - one step 5% maximum total harmonic distortion // ? digital control panel(s) digital metering engine parameters generator protection functions engine protection sae j1939 engine ecu communications windows ? -based software multilingual capability remote communications to rdp-110 remote annunciator 16 programmable contact inputs up to 11 contact outputs ul recognized, csa certi ed, ce approved event recording ip 54 front panel rating with integrated gasket nfpa110 compatible standard equipment* // ? mtu onsite energy is a single source supplier // ? global product support // ? 2 year standard warranty // ? 6.8l engine - 6.8 liter displacement - 4-cycle // ? 3-way catalyst // ? optional fuels: lp liquid and dual fuel // ? engine-generator resilient mounted // ? complete range of accessories // ? generator - brushless, rotating field generator - 2/3 pitch windings - 300% short circuit capability // ? digital control panel(s) - ul recognized, csa certi ed, nfpa 110 - complete system metering - lcd display // ? cooling system - integral set-mounted - engine driven fan standard features* * represents standard product only. consult factory/mtu onsite energy distributor for additional con gurations.
3 // / ? / GS100-6S // ? engine manufacturer ford model 6.8l v10 type 4-cycle aspiration turbocharged arrangement 10-v displacement: l (in 3 ) 6.8 (415) bore: cm (in) 90.2 (3.55) stroke: cm (in) 105.8 (4.17) compression ratio 9:1 rated rpm 1,800 engine governor bosch maximum power (ng): kwm (bhp) 132 (177) maximum power (lp): kwm (bhp) 132 (177) speed regulation c/f air cleaner dry // ? liquid capacity (lubrication) total oil system: l (gal) 5.7 (1.5) engine jacket water capacity: l (gal) 6 (1.6) system coolant capacity: l (gal) 27.47 (7.25) // ? electrical electric volts dc 12 cold cranking amps under -17.8 c (0 f) 925 // ? fuel inlet fuel supply connection size 1 1/2? npt fuel supply pressure: mm h 2 0 (in. h 2 0) 178?279 (7?11) // ? fuel consumption (ng-1000 btu/ft 3 / lp-2500 btu/ft 3 ) ng lpg at 100% of power rating: m 3 /hr (ft 3 /hr) 31.15 (1,100) 14.49 (511.5) at 75% of power rating: m 3 /hr (ft 3 /hr) 23.67 (835.9) 11.32 (400) at 50% of power rating: m 3 /hr (ft 3 /hr) 16.2 (520.1) 8.07 (284.8) // ? cooling - radiator system ambient capacity of radiator: c (f) 50 (122) maximum restriction of cooling air, intake, and discharge side of rad.: kpa (in. h 2 0) 0.12 (0.5) water pump capacity: l/min (gpm) 123 (32.5) heat rejection to coolant: kw (btum) 81.29 (4,623) heat radiated to ambient: kw (btum) 41.54 (2,362) fan power: kw (hp) 4.1 (5.5) 4.1 (5.5) // ? air requirements aspirating: *m 3 /min (scfm) 5.91 (208.7) air flow required for rad. cooled unit: *m 3 /min (scfm) 25 4.9 (9,001.7) remote cooled applications; air flow required for dissipation of radiated gen-set heat for a max of 25 f rise: *m 3 /min (scfm) 150.9 (5,329) * air density = 1.184 kg/m 3 (0.0739 lbm/ft 3 ) // ? exhaust system gas temp. (stack): c (f) 716.1 (1,321) gas volume at stack temp: m 3 /min (cfm) 20.2 (713.4) maximum allowable back pressure: kpa (in. h 2 0) 6.23 (25) application data
4 // / ? / GS100-6S sound data unit type standby full load (ng) standby full load (lp) level 0: open power unit db(a) 77.2 77.3 ? mtu onsite energy. subject to alteration due to technological advances. oe 23 680 (72 3e) 2014-01 weights and dimensions system dimensions (l x w x h) weight (dry) opu 2,199 x 1,158 x 1,556 mm (86.6 x 45.6 x 61.25 in) 1,163.9 kg (2,566 lb) drawing above for illustration purposes only, based on standard open power 480 volt generator set. lengths may vary with other voltages. do not use for installation design. see website for unit speci c template drawings. weights and dimensions are based on open power units and are estimates only. consult the factory for accurate weights and dimen sions for your speci c generator set. emissions data fuel type thc + no x co natural gas 0.44 0.20 liquid propane 0.12 0.09 all units are in g/hp-hr. engine meets epa 40 cfr part 60/1048 speci cations. rating definitions and conditions // ? standby ratings apply to installations served by a reliable utility source. the standby rating is applicable to varying loads for the duration of a power outage. no overload capability for this rating. ratings are in accordance with iso 3046-1, bs 5514, as 2789, and din 6271. // ? deration factor: altitude : consult your local mtu onsite energy power generation distributor for altitude derations. temperature : consult your local mtu onsite energy power generation distributor for temperature derations. sound data is provided at 7 m (23 ft). generator set tested in accordance with iso 8528-10 and with in nite exhaust. materials and speci cations subject to change without notice. c/f = consult factory/mtu onsite energy distributor mtu onsite energy a rolls-royce power systems brand www.mtuonsiteenergy.com


▲Up To Search▲   

 
Price & Availability of GS100-6S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X